117 Series Pressure Switch (H117 Models 520-525)
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Buna N diaphragm and O-ring with epoxy coated aluminum 1/2” NPT (female) pressure connection; large 0.72” orifice for clean-out purposes
0 / 5
117 Series Pressure Switch (H117 Models 530-535 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Welded 316L stainless steel diaphragm and 1/2” NPT (female) pressure connection, large 0.72” orifice for clean-out purposes
0 / 5
117 Series Pressure Switch (H117 Models 565-567 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

1.5” flush mount, welded 316L stainless steel diaphragm and pressure connection.

0 / 5
117 Series Pressure Switch (H117 Models 171-174 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Welded 316L stainless steel diaphragm and 1/2” NPT (female) pressure connection, large 0.72” orifice for clean-out purposes; NACE MR-0175 compliant

0 / 5
117 Series Pressure Switch (H117 Models 183-189 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

316L stainless steel diaphragm (optional HastelloyR C or MonelR); VitonR GLT O-ring (optional KalrezR, Ethylene Propylene, or AflasR); 316 stainless steel 1/2” NPT (female) pressure connection (optional HastelloyR C or MonelR), large 0.72” orifice for clean-out purposes. Models 188 and 189 have a 316L stainless steel 1/2” NPT (female) pressure connection; NACE MR 0175 compliant.

0 / 5
117 Series Pressure Switch (H117 Models 483-489 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

316L stainless steel diaphragm (optional HastelloyR C or MonelR); VitonR GLT O-ring (optional KalrezR, Ethylene Propylene, or AflasR); 316 stainless steel 1/2” NPT (female) pressure connection (optional HastelloyR C or MonelR), large 0.72” orifice for clean-out purposes. Models 188 and 189 have a 316L stainless steel 1/2” NPT (female) pressure connection; NACE MR 0175 compliant.

0 / 5
117 Series Pressure Switch (H117 Model 218)
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

218 - Set Point Range: 30 “Hg Vac to 0 psi /Deadband: 2 to 5 “Hg /Over Range Pressure : 3 psi / Proof Pressure: 30psi
0 / 5
117 Series Pressure Switch (H117 Models 358-376 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Welded 316L stainless steel bellows and 1/4” NPT (female) pressure connection
0 / 5
117 Series Pressure Switch (H117 Models 190-194 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Welded 316 stainless steel diaphragm and 1/2” NPT (female) pressure connection, large 0.72” orifice for clean-out purposes; NACE MR0175 compliant (except model 194)
0 / 5
117 Series Pressure Switch (H117 Models 490-494 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Welded 316 stainless steel diaphragm and 1/2” NPT (female) pressure connection, 0.06” orifice to dampen pulsations; NACE MR0175 compliant (except model 494)
0 / 5
117 Series Pressure Switch (H117 Models 701-706 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

H117 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale.

Buna N diaphragm and O-ring with 316 stainless steel 1/4” NPT (female) pressure connection; option M540 VitonR diaphragm and O-ring available
0 / 5
117 Series Differential Pressure Switch (H117K Models 540-548 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

Type H117K - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale

Buna N diaphragm and sealing diaphragms with epoxy coated aluminum 1/8” NPT (female) pressure connections.
0 / 5
117 Series Temperature Switch (B117 Models 120-121 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

Type B117 - Immersion stem; One SPDT output; epoxy coated enclosure; internal adjustment with reference dial
0 / 5
117 Series Temperature Switch (E117 )
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.

Type E117 - Bulb and capillary; One SPDT output; epoxy coated enclosure; internal adjustment with reference dial